loop for ice rink

Geothermal leads to optimum ice conditions at new Hearst Ontario curling rink

FOR IMMEDIATE RELEASE
March 29, 2012

Hearst, Ontario – Inconsistent ice conditions have become a thing of the past at the Hearst Community Curling Club in Northeastern Ontario thanks to the geothermal technology installed in the club’s new building. The four-sheet curling rink marked its official opening on February 25th and is quickly realizing the benefits of this renewable energy alternative over conventional heating and cooling systems in a community characterized by winter temperatures of -40°C.

“In our old building, we could have as much as a 16 degree swing in temperature from one section of the ice to another making for less than optimum curling conditions,” says Larry Wesley, the club’s ice technician. “Now, we’re able to keep the ice temperature on all four sheets at a relatively constant -5°C, with never more than a two degree fluctuation, making the surfaces ideal for curling.” Maintaining a consistent temperature across the entire ice surface contributes to consistent rock speed and curl.

When the curling club’s aging facilities lead to plans to construct a new building, the club turned to GeoSmart Energy, and local GeoSmart dealers Canadian Geo and Greenviro Engineering to explore the feasibility of using geothermal technology to heat and cool the building and to help maintain consistent ice conditions. Cal Delorey from Gagnon & Associates was instrumental in bringing the parties to the table and championing the benefits of geo as a renewable energy solution. What started out as a simple diagram on a packaging from Viagra in a Hearst, Ontario restaurant blossomed into one of the most efficient curling rinks in the province.

George Njegovan of Greenviro Engineering took that napkin and transformed the diagram into a geothermal blueprint for success.

More than 30,000 feet of horizontally looped ¾” polyethylene pipe was buried in the ground outside the building, where it is tapping into the earth’s natural heating and cooling properties to consistently and evenly distribute warm or cool air throughout the curling club during the year. The system features five separate 10-tonne headers each of which runs separately into the building.

The loop system feeds into 17 circulating heat pumps inside the building. Six 5-tonne GeoSmart Premium H water to water units are being utilized to freeze the four curling sheets. Six 3-tonne GeoSmart Premium G forced air units, each featuring a secondary compressor for dehumidification, have been installed around the four sheets to help maintain the ice at -5°C. Low humidity is an important factor in preventing the condensation of water on the ice. Two 4-tonne GeoSmart Premium G forced air units are located at the front of the building on the first and second floors which feature a banquet hall, viewing area and office space and are used to help maintain a comfortable temperature in these areas.

A series of ¾” pipes is buried about 1¼” below the 60′ x 120′ concrete floors that make up each sheet of ice. A water solution from an 850 gallon cold tank circulates through the pipes beneath the ice during the freezing of the ice and to help maintain the ice temperature.

“While the system was expected to generate an ice freeze of 1¼” on top of each rink’s concrete floor,” says Jay Labbe of Canadian Geo whose company completed the installation, “it has far exceeded expectations, generating a 3″ base instead.”

One of the by-products when freezing the ice is extracting heat. While the Premium H water to water is used to circulate water from the 850 gallon cold tank to freeze the ice, it also needs to get rid of excess heat. This excess heat is transferred into an 850 gallon hot water tank, essentially providing the club with free hot water. When the hot water tank gets hot, the forced air units extract the heat to heat the remainder of the building.

The configuration of the forced air units in the rink area allows for quality air circulation by forcing the air into a circular motion which also contributes to maintaining a more consistent temperature at ice level.

“The forced air units are all on tri-thermostats,” notes Steve Marco, Operations Manager, GeoSmart Energy. “This means the club can monitor the system electronically from remote locations pretty much anywhere in the world, including the ability to turn the system on and off.”

The system was also designed to give the club the flexibility to maintain the ice on the rinks all year round or to run just one or two rinks at a time, allowing for maximum cooling and heating efficiency.

“We run four sheets five nights a week during the winter,” says Larry Wesley. “That means we have 32 people in here curling every night, so it’s important that we are able to provide the best possible curling conditions, and with this new geothermal technology, we’re able to do just that. The ambient temperature is perfect.”

  loop for ice rink

finished ice rink

GeoSmart Energy
GeoSmart Energy is a leading geothermal heating and cooling supplier to residential and commercial markets. As one of the largest purveyors of geothermal technology and training, GeoSmart is continually asked globally for their knowledge and geothermal implementation expertise. Visit us at www.geosmartenergy.com

Photos: high resolution photographs of the event are available upon request.

Media Contacts:
Robert J. Longphee, Director, Marketing & National Business Development

GeoSmart Energy
290 Pinebush Road, Cambridge, ON  N1T 1Z6
t: 866.310.6690
f: 866.533.3889